Construction
- Conductor Material
- Copper
- Conductor Form
- Stranded
- Insulation Material
- Mica Tape
- Metal Sheath Material
- Copper
- Branch Joint
- Prefabricated Branch Connection
Features
+
- Flame Retardant
- Yes
- Fire Resistant
- Yes
- Water Resistant
- Yes
Operating Conditions
+
- Maximum Conductor Temperature
≤ 90 °C
- Ambient Temperature
−15 to 90 °C
- Minimum Laying Temperature
≥ 0 °C
- Short-circuit Temperature
≤ 250 °C · Maximum duration: 5 s
Bending & Motion
+
- Minimum Bending Radius · Fixed
≥ 15 D
Electrical & Test Requirements
+
Construction & Material Notes
+
- Construction Notes
- Main and branch lengths and branch positions are determined from site measurements.
- Factory crimped Copper branch connectors with moulded joints.
- Prepared suspension terminations support the hanging cable.
- Manufacturing Description
Flexible construction permits continuous manufacture, delivery on drums and conventional cable-laying methods.
- Conductor Copper Purity
- Value
- 99.99 %
- Material
- oxygen free Copper
- Branch Joint Features
- Values
- Vibration resistance · Gas-tight sealed joint · Water resistance · Fire resistance
- Construction Details
- Metal Sheath Form
- Corrugated
- Main Conductor Continuous
- Yes
- Connector Material
- Copper Busbar
- Connection Method
- Crimped
- Joint Body Process
- Moulded
- Joint Enclosure
- Fire Resistant Insulating Body
- Insulation Component
- Mica Tape
Applications
+
- Applications
- Power distribution, lighting and fire-safety circuits
- High-rise and public buildings, hospitals and schools
- Industrial installations requiring fire-resistant circuits
Installation & Ordering
+
- Installation
- Do not twist, knot or drag the cable across abrasive surfaces.
- Fix at bends and on both sides of intermediate joints.
- Separate single-core circuits by at least twice the cable diameter; closer spacing requires current-rating derating.
- Use an outer protective sheath in corrosive environments and for buried or conduit installation.
- Single-core Fixing
Do not use ferromagnetic material such as iron wire to tie or fix single-core cables.
- Maximum Fixing Spacing
- D < 9 mm · Horizontal Spacing
- ≤ 600 mm
- D < 9 mm · Vertical Spacing
- ≤ 800 mm
- 9 <= D < 15 mm · Horizontal Spacing
- ≤ 900 mm
- 9 <= D < 15 mm · Vertical Spacing
- ≤ 1,200 mm
- D >= 15 mm · Horizontal Spacing
- ≤ 1,500 mm
- D >= 15 mm · Vertical Spacing
- ≤ 2,000 mm
- Terminations
- Seal cut ends promptly against moisture if the cable will not be terminated immediately.
- Follow the manufacturer's termination and jointing procedure.
- Keep metallic sheath swarf out of the insulation and recheck insulation resistance during termination.
- Branch Installation
- Select suspension heads, cross-arm hangers and fixing clamps for the building layout.
- Sealed branch joints are intended for damp, outdoor or buried installation.
- Continuous Length Capability
- Maximum
- 2000 m
- Expansion & Vibration Bends
- Minimum Radius (D)
- 6
- Shapes
- S · omega
- Natural Meander Allowance
- Maximum Excursion (D)
- 2
- Maximum Is Exclusive
- Yes
- Ferromagnetic Conduit
- Individual Single Core In Ferromagnetic Conduit Permitted
- No
- Branch Clamp Spacing
- Minimum
- 0.6 m
- Maximum
- 0.8 m
- Custom Options Available
- Yes
Specification Ranges
Core & conductor combinations
- Core count
- 1–5
- Cross section (mm²)
- 10–400
Product Record
CU/Mica Tape 0.6/1kV Flame-retardant Fire-resistant Prefabricated Branch Cable
Model: YFD-RTTZ
Reference: xr-mineral-prefabricated-branch-0.6-1-yfd_rttz
Catalogue Tags: mineral-insulated · prefabricated-branch · power-cables · fire-resistant · flame-retardant
View the Public JSON Record↗View the Standards Data↗