YFD-BTLY — representative 1-core cable with matching cross section. Corrugated Aluminum Sheath shown in the cutaway.
View Full-size Cross Section ↗

Prefabricated Branch Cable

CU/Mica Tape/Polyolefin 0.6/1kV LSZH Flame-retardant Fire-resistant Prefabricated Branch Cable

Model / YFD-BTLY

Rated Voltage
0.6/1kV
Materials
CU/Mica Tape/Polyolefin
Custom Option Standards
  • BS 6387 — Fire Test
  • BS 8491 — Fire Test
Features
LSZH / Flame-retardant / Fire-resistant / Water-resistant
Temperature

Max. conductor: ≤ 90 °C

Download Product Data ↓

Product Reference: xr-mineral-prefabricated-branch-0.6-1-yfd_btly

Construction

Conductor Material
Copper
Conductor Form
Stranded
Insulation Material
Mica Tape
Metal Sheath Material
Aluminum
Outer Sheath Material
Polyolefin
Branch Joint
Prefabricated Branch Connection
Wrapping
Inorganic Composite Fire Resistant Tape
Fire Barrier
Ceramifiable Inorganic Composite

Features

Flame Retardant
Yes
Fire Resistant
Yes
Low Smoke Halogen Free
Yes
Water Resistant
Yes

Operating Conditions

Maximum Conductor Temperature

≤ 90 °C

Ambient Temperature

−15 to 90 °C

Minimum Laying Temperature

≥ 0 °C

Short-circuit Temperature

≤ 250 °C · Maximum duration: 5 s

Bending & Motion

Minimum Bending Radius
1 core
≥ 20 D
3 cores
≥ 15 D

Electrical & Test Requirements

Fire tests

TestTemperature (°C)Exposure
Fire Only800Fire: 90 min
BS6387 C950Fire: 180 min
BS6387 W650Initial fire: 15 min Fire + water: 15 min
BS6387 Z950Fire + mechanical shock: 15 min

Construction & Material Notes

Construction Notes
  • Main and branch lengths and branch positions are determined from site measurements.
  • Factory crimped Copper branch connectors with moulded joints.
  • Prepared suspension terminations support the hanging cable.
Manufacturing Description

Flexible construction permits continuous manufacture, delivery on drums and conventional cable-laying methods.

Conductor Copper Purity
Value
99.99 %
Material
oxygen free Copper
Branch Joint Features
Values
Vibration resistance · Gas-tight sealed joint · Water resistance · Fire resistance
Construction Details
Metal Sheath Form
Corrugated
Main Conductor Continuous
Yes
Connector Material
Copper Busbar
Connection Method
Crimped
Joint Body Process
Moulded
Joint Enclosure
Fire Resistant Insulating Body
Insulation Component
Mica Tape

Applications

Applications
  • Power distribution, lighting and fire-safety circuits
  • High-rise and public buildings, hospitals and schools
  • Industrial installations requiring fire-resistant circuits

Installation & Ordering

Installation
  • Do not twist, knot or drag the cable across abrasive surfaces.
  • Fix at bends and on both sides of intermediate joints.
  • Separate single-core circuits by at least twice the cable diameter; closer spacing requires current-rating derating.
  • Use an outer protective sheath in corrosive environments and for buried or conduit installation.
Single-core Fixing

Do not use ferromagnetic material such as iron wire to tie or fix single-core cables.

Maximum Fixing Spacing
D < 9 mm · Horizontal Spacing
≤ 600 mm
D < 9 mm · Vertical Spacing
≤ 800 mm
9 <= D < 15 mm · Horizontal Spacing
≤ 900 mm
9 <= D < 15 mm · Vertical Spacing
≤ 1,200 mm
D >= 15 mm · Horizontal Spacing
≤ 1,500 mm
D >= 15 mm · Vertical Spacing
≤ 2,000 mm
Terminations
  • Seal cut ends promptly against moisture if the cable will not be terminated immediately.
  • Follow the manufacturer's termination and jointing procedure.
  • Keep metallic sheath swarf out of the insulation and recheck insulation resistance during termination.
Branch Installation
  • Select suspension heads, cross-arm hangers and fixing clamps for the building layout.
  • Sealed branch joints are intended for damp, outdoor or buried installation.
Continuous Length Capability
Maximum
2000 m
Expansion & Vibration Bends
Minimum Radius (D)
6
Shapes
S · omega
Natural Meander Allowance
Maximum Excursion (D)
2
Maximum Is Exclusive
Yes

Support span

Cable diameter D (mm)Horizontal max. (mm)Vertical max. (mm)
D ≤ 204001500
D > 208001000
Ferromagnetic Conduit
Individual Single Core In Ferromagnetic Conduit Permitted
No
Branch Clamp Spacing
Minimum
0.6 m
Maximum
0.8 m
Custom Options Available
Yes

Accessories

TypeModels
Suspension HeadY-1 · Y-2 · Y-3 · Y-4 · Y-5 · Y-6 · Y-7 · Y-8 · Y-9 · Y-10
Cross Arm HangerHD-01 · HD-02 · HD-03 · HD-04 · HD-11 · HD-12 · HD-13
Support ClampJJ-01 · JJ-02 · JJ-03 · JJ-04 · JJ-11 · JJ-12 · JJ-13

Specification Ranges

Core & conductor combinations

Core configurationCross section (mm²)
1 core10–630
2 cores / 3 cores / 4 cores / 3+1 core2.5–240
5 cores / 3+2 cores / 4+1 core2.5–240

Product Record

CU/Mica Tape/Polyolefin 0.6/1kV LSZH Flame-retardant Fire-resistant Prefabricated Branch Cable

Model: YFD-BTLY
Reference: xr-mineral-prefabricated-branch-0.6-1-yfd_btly

Catalogue Tags: mineral-insulated · prefabricated-branch · power-cables · fire-resistant · flame-retardant · lszh

View the Public JSON Record

View the Standards Data