WDZB1N-YJY23 — representative 3-core cable with matching cross section.
View Full-size Cross Section ↗

Power Cable

CU/XLPE/Polyolefin 8.7/15kV LSZH Flame-retardant B1 Fire-resistant Screened Steel Tape Armored Power Cable

Model / WDZB1N-YJY23-MV

Rated Voltage
8.7/15kV
Materials
CU/XLPE/Polyolefin
Custom Option Standards
  • IEC 60502-2
Features
LSZH / Flame-retardant B1 / Fire-resistant / Screened / Steel Tape Armored
Temperature

Max. conductor: ≤ 90 °C

Download Product Data ↓

Product Reference: xr-b1-power-8.7-15-wdzb1n_yjy23

Construction

Conductor Material
Copper
Conductor Form
Stranded
Insulation Material
XLPE
Each core Conductor Screen
Yes
Each core Insulation Screen
Yes
Each core Metal Screen
Yes
Armor
Steel Tape
Outer Sheath Material
Polyolefin
Fire Barrier
Yes
Oxygen Barrier
Yes

Features

Flame Retardant
Yes
Flame Retardant Class
B1
Fire Resistant
Yes
Low Smoke Halogen Free
Yes

Operating Conditions

Maximum Conductor Temperature

≤ 90 °C

Ambient Temperature

−15 to 90 °C

Minimum Laying Temperature

≥ 0 °C

Short-circuit Temperature

≤ 250 °C · Maximum duration: 5 s

Bending & Motion

Minimum Bending Radius
1 core
≥ 15 D
Multicore
≥ 12 D
Minimum Bending Radius · At Joints
1 core
≥ 12 D
Multicore
≥ 10 D

Electrical & Test Requirements

Reaction-to-fire Requirements
Classification
B1
Test Standard
GB 31247
Flame spread
≤ 1.5 m
Peak heat release rate
≤ 30 kW
Total heat release
≤ 15 MJ · Duration: 1,200 s
Fire growth rate index
≤ 150 W/s
Peak smoke production rate
≤ 0.25 m²/s
Total smoke production
≤ 50 m² · Duration: 1,200 s
Vertical flame spread
≤ 425 mm

Construction & Material Notes

Conductor Material
Copper Purity (%)
99.99
Material Grade
oxygen free Copper

Applications

Applications
  • Metro stations and transport hubs
  • Airports
  • Hospitals
  • High-rise buildings
  • Shopping centres, hotels and exhibition centres

Installation & Ordering

Handling
  • Keep drums upright and secure during lifting, transport and storage.
  • Inspect for damage and check insulation resistance before installation.
  • Provide allowance for vibration, thermal expansion and building movement.
Installation
  • Avoid twisting, knotting and dragging across sharp or abrasive surfaces.
  • Fix the cable at bends and on both sides of joints.
  • Do not use ferromagnetic ties or clamps around single-core cables.
  • Provide mechanical protection where damage may occur.
Natural Snaking Amplitude
Less Than (× Outside Diameter): 2
Single Core Circuit Separation
Minimum (× Outside Diameter): 2 · Closer Spacing Requires Ampacity Derating: Yes
Single Core Fixings Must Be Nonmagnetic
Yes

Fixing-point spacing

Cable diameter D (mm)Horizontal max. (mm)Vertical max. (mm)
D < 9600800
9 ≤ D < 159001200
D ≥ 1515002000
Natural Snaking Amplitude
Less Than (× Outside Diameter): 2
Single Core Circuit Separation
Minimum (× Outside Diameter): 2 · Closer Spacing Requires Ampacity Derating: Yes
Single Core Fixings Must Be Nonmagnetic
Yes

Support span

Cable diameter D (mm)Horizontal max. (mm)Vertical max. (mm)
D ≤ 204001500
D > 208001000
Movement Allowance Bends
Shapes
S · omega
Minimum Radius (× Outside Diameter)
15

Specification Ranges

Core & conductor combinations

Core configurationCross section (mm²)
1 core25–630
3 cores25–400

Product Record

CU/XLPE/Polyolefin 8.7/15kV LSZH Flame-retardant B1 Fire-resistant Screened Steel Tape Armored Power Cable

Model: WDZB1N-YJY23-MV
Reference: xr-b1-power-8.7-15-wdzb1n_yjy23

Catalogue Tags: power-cables · medium-voltage · fire-resistant · flame-retardant · b1 · lszh · screened · armored

View the Public JSON Record

View the Standards Data