Encoder Cable
Tinned CU/Special PVC/PVC 300/300V Flame-retardant Screened Encoder Cable
Model / D02ES
300/300VView Details →

Encoder Cable
Model / D10ES
Fixed: −15 to 80 °C
Moving: −5 to 80 °C
Product Reference: xr-industrial-d10es-d10es
Product Details
−15 to 80 °C
−5 to 80 °C
≥ 6 D
≥ 8 D
≤ 5 m/s
≤ 3 m/s
≤ 50 m/s²
50 m
10,000,000 cycles
≥ 20 MΩ·km
1,500 V
6 · IEC 60228 / VDE 0295
The two insulated wires of each pair have the same colour.
Servo encoder and controller signal connections with repeated drag-chain movement.
| Cross section (mm²) | Cores | Pairs | Outside diameter (mm) | Mass (kg/km) |
|---|---|---|---|---|
| 0.2 | 4 | 2 | 6 | 53 |
| 0.2 | 6 | 3 | 6.3 | 61 |
| 0.2 | 8 | 4 | 7 | 76 |
| 0.2 | 10 | 5 | 7.4 | 86 |
| 0.2 | 12 | 6 | 8.2 | 106 |
| 0.2 | 14 | 7 | 8.6 | 115 |
| 0.2 | 16 | 8 | 9 | 121 |
| 0.2 | 20 | 10 | 10 | 145 |
| 0.2 | 24 | 12 | 10.5 | 168 |
| 0.2 | 26 | 13 | 10.8 | 193 |
| 0.3 | 4 | 2 | 6.2 | 59 |
| 0.3 | 6 | 3 | 6.5 | 63 |
| 0.3 | 8 | 4 | 7.4 | 87 |
| 0.3 | 10 | 5 | 7.8 | 103 |
| 0.3 | 12 | 6 | 8.2 | 115 |
| 0.3 | 14 | 7 | 8.8 | 126 |
| 0.3 | 16 | 8 | 9.5 | 133 |
| 0.3 | 20 | 10 | 10.6 | 168 |
| 0.3 | 24 | 12 | 10.8 | 230 |
| 0.3 | 26 | 13 | 11 | 242 |
| Pairs | Pair construction | Cross section (mm²) |
|---|---|---|
| 2 · 3 · 4 · 5 · 6 · 7 · 8 · 10 · 12 · 13 | 2P | 0.2 |
| 2 · 3 · 4 · 5 · 6 · 7 · 8 · 10 · 12 · 13 | 2P | 0.3 |
Tinned CU/TPE/PVC 300/300V Flame-retardant Screened Encoder Cable
Model: D10ES
Reference: xr-industrial-d10es-d10es
Catalogue Tags: industrial-flexible · drag-chain · industrial-encoder · flame-retardant · screened
View the Public JSON Record