H1Z2Z2-K — representative 1-core cable with matching cross section.
View Full-size Cross Section ↗

Photovoltaic Cable

Tinned CU/Cross-linked Polymer/Cross-linked Polymer AC 1/1kV; DC 1.5kV LSZH Flame-retardant Photovoltaic Cable

Model / H1Z2Z2-K

Rated Voltage
AC 1/1kV; DC 1.5kV
Materials
Tinned CU/Cross-linked Polymer/Cross-linked Polymer
Standards
  • EN 50618
Features
LSZH / Flame-retardant / UV-resistant / Ozone-resistant / Water-resistant
Temperature

Fixed: -40 to 90 °C

Download Product Data ↓

Product Reference: xr-h1z2z2-k-photovoltaic-h1z2z2_k

Construction

Conductor Material
Tinned Copper
Conductor Form
Flexible Stranded
Insulation Material
Crosslinked Polymer
Shape
Round
Outer Sheath Material
Crosslinked Polymer

Features

Flame Retardant
Yes
Low Smoke Halogen Free
Yes
UV Resistant
Yes
Ozone Resistant
Yes
Water Resistant
Yes

Operating Conditions

Fixed installation
-40–90 °C
Ambient temperature
-40–90 °C
Short-circuit temperature
≤ 250 °C · up to 5 s

Conductor temperature limits

TemperatureOperating condition
90 °CNormal continuous operation
120 °CUp to 20000 h in total; ambient ≤ 90 °C

Bending & Motion

Minimum bending radius · fixed
≥ 5 × cable diameter

Electrical & Test Requirements

Voltage test
6500 V AC
Flame tests
IEC/EN 60332-1-2

Air-temperature derating

Air temperature (°C)Factor
≤ 601
700.91
800.82
900.71
1000.58
1100.41

Rated voltage

SupplyU₀ (V)U (V)
AC10001000
DC15001500
Maximum permitted voltage
≤ 1800 V DC · unearthed circuit, between conductors, not under load
Water resistance
AD8
LSZH tests
IEC/EN 60754-1/2 / IEC/EN 61034-1/2 / EN 50267-2-2
Ozone & UV tests
EN 60811-403 / EN 50396 / EN ISO 4892-1/3
Reference standards
EN 50618 / TUV 2 PfG 1169/08.2007 / EN 50288-3-7 / EN 60068-2-78 / EN 50395

Construction & Material Notes

Conductor class
Class 5 · EN 60228
Construction
Cross-linked insulation and sheath. The available sources do not identify the exact polymer formulation or cross-linking process.
Sheath colour
Black

Applications

Applications
Photovoltaic system wiring, particularly on the DC side.

Installation & Ordering

Selection
The permitted 1.8 kV DC maximum applies between conductors in an unearthed circuit not under load; it is not the rated voltage.
Installation
Fixed installation indoors or outdoors. / Installation in conduits or systems. / Impact tested and suitable for direct burial.

Current-carrying Capacity

Core count
1

Dimensions & mass

Section (mm²)Outside diameter (mm)Mass (kg/km)
1.54.636
2.5546
45.662
66.182
107.1125
168.5190
2510.4285
3511.5385

Electrical & mechanical values

Section (mm²)Max. resistance · 20 °C (Ω/km)Max. resistance · 90 °C (Ω/km)Voltage drop (mV/A/m)Operating tensile force (N)
1.513.717.46838.222
2.58.2110.4682337
45.096.4914.360
63.394.3229.4990
101.952.4865.46150
161.241.5813.47240
250.7951.0132.23375
350.5650.721.58525

Reference current

Section (mm²)Single cable in air (A)Single cable on surface (A)Two cables adjacent on surface (A)
1.5302924
2.5413933
4555244
6706757
10989379
16132125107
25176167142
35218207176

Specification Ranges

Core & conductor combinations

Core configurationCross section (mm²)
11.5 · 2.5 · 4 · 6 · 10 · 16 · 25 · 35

Product Record

Tinned CU/Cross-linked Polymer/Cross-linked Polymer AC 1/1kV; DC 1.5kV LSZH Flame-retardant Photovoltaic Cable

Model: H1Z2Z2-K
Reference: xr-h1z2z2-k-photovoltaic-h1z2z2_k

Catalogue Tags: photovoltaic · power-cables · flame-retardant · lszh

View the Public JSON Record

View the Standards Data