  "product_id": "xr-steel-core-al-overhead-jklgyj_q",
  "family_id": "steel-core-al-overhead",
  "model": "JKLGYJ/Q",
  "source_notation": "JKLGYJ/Q",
  "rated_voltage": "10kV",
  "specification_ranges": [
    {
      "profile_id": "10kv-source-table",
      "range_type": "source_table_exact_or_conditioned_combination",
      "composition": {
        "aluminum_steel_area_pairs_mm2": [
          "10/2",
          "16/3",
          "25/4",
          "35/6",
          "50/8",
          "50/30",
          "70/10",
          "70/40",
          "95/15",
          "95/20",
          "95/55",
          "120/7",
          "120/20",
          "120/25",
          "120/70",
          "150/8",
          "150/20",
          "150/25",
          "150/35",
          "185/10",
          "185/25",
          "185/30",
          "185/45",
          "210/10",
          "210/25",
          "210/35",
          "210/50",
          "240/30",
          "240/40",
          "240/55"
        ]
      }
    }
  ],
  "construction": {
    "conductor_material": "steel_reinforced_aluminum",
    "insulation_material": "xlpe",
    "outer_sheath_material": "none",
    "screen": {
      "present": false,
      "type": "none"
    },
    "armor": {
      "present": false,
      "type": "none"
    },
    "conductor_form": "stranded",
    "conductor_screen_cases": [
      {
        "rated_voltage": "10kV",
        "present": false,
        "type": "none"
      }
    ]
  },
  "functions": {},
  "cross_section_examples": [
    {
      "example_id": "steel-al-10kV-light",
      "basis": "manual_diagram",
      "scope": "model_diagram",
      "not_to_scale": true,
      "configuration_is_orderable_specification": false,
      "nodes": [
        {
          "node_id": "cable",
          "parent_id": null,
          "kind": "assembly",
          "count": 1,
          "layers": []
        },
        {
          "node_id": "aluminum-conductor",
          "parent_id": "cable",
          "kind": "core",
          "count": 1,
          "layers": [
            {
              "kind": "conductor",
              "material": "aluminum",
              "form": "stranded"
            },
            {
              "kind": "insulation",
              "material": "xlpe"
            }
          ]
        },
        {
          "node_id": "steel-centre",
          "parent_id": "aluminum-conductor",
          "kind": "reinforcement",
          "count": 1,
          "layers": [],
          "material": "steel"
        }
      ],
      "illustrated_counts": {
        "cores": 1,
        "groups": 0,
        "tubes": 0,
        "reinforcements": 1
      },
      "applicable_rated_voltage": "10kV",
      "note": "One steel-reinforced aluminium conductor. The central steel reinforcement is not a separate insulated electrical core. The drawn strand texture does not specify a manufacturing wire count."
    }
  ],
  "technical_details": {
    "applications": {
      "basis": "declared",
      "values": [
        "Overhead power transmission and distribution lines"
      ]
    },
    "minimum_laying_temperature": {
      "basis": "declared",
      "unit": "degC",
      "min": -20
    },
    "minimum_bending_radius": {
      "basis": "declared",
      "cases": [
        {
          "core_configuration": "1 core",
          "formula": "20 * (D + d)",
          "tolerance_percent": 5,
          "unit": "mm"
        },
        {
          "core_configuration": "Multicore",
          "formula": "15 * (D + d)",
          "tolerance_percent": 5,
          "unit": "mm"
        }
      ],
      "diameter_definition": "D is the actual cable diameter in mm; d is the actual conductor diameter in mm.",
      "conditions": "The source prints +/-5% with the bending expression. For JKLGYJ this paragraph is headed 10kV; do not apply it automatically to the 1kV configuration."
    },
    "maximum_conductor_temperature": {
      "basis": "declared",
      "unit": "degC",
      "max": 90,
      "conditions": "Continuous operation"
    },
    "short_circuit_temperature": {
      "basis": "declared",
      "unit": "degC",
      "max": 250,
      "maximum_duration_s": 5
    },
    "dimensional_table": {
      "basis": "declared",
      "reported_row_count": 27,
      "rows": [
        {
          "source_row_id": "10kV-light-25/4",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 25
            },
            {
              "material": "steel",
              "cross_section_mm2": 4
            }
          ],
          "conductor_diameter_mm": 7,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 12,
          "mass_kg_per_km": 192.1,
          "minimum_conductor_breaking_force_N": 9290
        },
        {
          "source_row_id": "10kV-light-35/6",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 35
            },
            {
              "material": "steel",
              "cross_section_mm2": 6
            }
          ],
          "conductor_diameter_mm": 8.2,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 13.2,
          "mass_kg_per_km": 240.4,
          "minimum_conductor_breaking_force_N": 12630
        },
        {
          "source_row_id": "10kV-light-50/8",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 50
            },
            {
              "material": "steel",
              "cross_section_mm2": 8
            }
          ],
          "conductor_diameter_mm": 9.6,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 14.6,
          "mass_kg_per_km": 306.5,
          "minimum_conductor_breaking_force_N": 16870
        },
        {
          "source_row_id": "10kV-light-50/30",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 50
            },
            {
              "material": "steel",
              "cross_section_mm2": 30
            }
          ],
          "conductor_diameter_mm": 11.6,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 16.6,
          "mass_kg_per_km": 499.7,
          "minimum_conductor_breaking_force_N": 42620
        },
        {
          "source_row_id": "10kV-light-70/10",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 70
            },
            {
              "material": "steel",
              "cross_section_mm2": 10
            }
          ],
          "conductor_diameter_mm": 11.4,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 16.4,
          "mass_kg_per_km": 401.5,
          "minimum_conductor_breaking_force_N": 23390
        },
        {
          "source_row_id": "10kV-light-70/40",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 70
            },
            {
              "material": "steel",
              "cross_section_mm2": 40
            }
          ],
          "conductor_diameter_mm": 13.6,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 18.6,
          "mass_kg_per_km": 657.2,
          "minimum_conductor_breaking_force_N": 58330
        },
        {
          "source_row_id": "10kV-light-95/15",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 95
            },
            {
              "material": "steel",
              "cross_section_mm2": 15
            }
          ],
          "conductor_diameter_mm": 13.6,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 18.6,
          "mass_kg_per_km": 527.1,
          "minimum_conductor_breaking_force_N": 35000
        },
        {
          "source_row_id": "10kV-light-95/20",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 95
            },
            {
              "material": "steel",
              "cross_section_mm2": 20
            }
          ],
          "conductor_diameter_mm": 13.9,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 18.9,
          "mass_kg_per_km": 557.3,
          "minimum_conductor_breaking_force_N": 27200
        },
        {
          "source_row_id": "10kV-light-120/7",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 120
            },
            {
              "material": "steel",
              "cross_section_mm2": 7
            }
          ],
          "conductor_diameter_mm": 14.5,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 19.5,
          "mass_kg_per_km": 532.8,
          "minimum_conductor_breaking_force_N": 27570
        },
        {
          "source_row_id": "10kV-light-120/20",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 120
            },
            {
              "material": "steel",
              "cross_section_mm2": 20
            }
          ],
          "conductor_diameter_mm": 15.1,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 20.1,
          "mass_kg_per_km": 625.3,
          "minimum_conductor_breaking_force_N": 41000
        },
        {
          "source_row_id": "10kV-light-120/25",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 120
            },
            {
              "material": "steel",
              "cross_section_mm2": 25
            }
          ],
          "conductor_diameter_mm": 15.7,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 20.7,
          "mass_kg_per_km": 690.6,
          "minimum_conductor_breaking_force_N": 47880
        },
        {
          "source_row_id": "10kV-light-120/70",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 120
            },
            {
              "material": "steel",
              "cross_section_mm2": 70
            }
          ],
          "conductor_diameter_mm": 18,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 23,
          "mass_kg_per_km": 1078,
          "minimum_conductor_breaking_force_N": 98370
        },
        {
          "source_row_id": "10kV-light-150/8",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 150
            },
            {
              "material": "steel",
              "cross_section_mm2": 8
            }
          ],
          "conductor_diameter_mm": 16,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 21,
          "mass_kg_per_km": 627.8,
          "minimum_conductor_breaking_force_N": 32860
        },
        {
          "source_row_id": "10kV-light-150/20",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 150
            },
            {
              "material": "steel",
              "cross_section_mm2": 20
            }
          ],
          "conductor_diameter_mm": 16.7,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 21.7,
          "mass_kg_per_km": 721.2,
          "minimum_conductor_breaking_force_N": 46630
        },
        {
          "source_row_id": "10kV-light-150/25",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 150
            },
            {
              "material": "steel",
              "cross_section_mm2": 25
            }
          ],
          "conductor_diameter_mm": 17.1,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 22.1,
          "mass_kg_per_km": 776.4,
          "minimum_conductor_breaking_force_N": 54110
        },
        {
          "source_row_id": "10kV-light-150/35",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 150
            },
            {
              "material": "steel",
              "cross_section_mm2": 35
            }
          ],
          "conductor_diameter_mm": 17.5,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 22.5,
          "mass_kg_per_km": 854.8,
          "minimum_conductor_breaking_force_N": 65020
        },
        {
          "source_row_id": "10kV-light-185/10",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 185
            },
            {
              "material": "steel",
              "cross_section_mm2": 10
            }
          ],
          "conductor_diameter_mm": 18,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 23,
          "mass_kg_per_km": 767,
          "minimum_conductor_breaking_force_N": 40880
        },
        {
          "source_row_id": "10kV-light-185/25",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 185
            },
            {
              "material": "steel",
              "cross_section_mm2": 25
            }
          ],
          "conductor_diameter_mm": 18.9,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 23.9,
          "mass_kg_per_km": 896.5,
          "minimum_conductor_breaking_force_N": 59420
        },
        {
          "source_row_id": "10kV-light-185/30",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 185
            },
            {
              "material": "steel",
              "cross_section_mm2": 30
            }
          ],
          "conductor_diameter_mm": 18.9,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 23.9,
          "mass_kg_per_km": 922.8,
          "minimum_conductor_breaking_force_N": 64320
        },
        {
          "source_row_id": "10kV-light-185/45",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 185
            },
            {
              "material": "steel",
              "cross_section_mm2": 45
            }
          ],
          "conductor_diameter_mm": 19.6,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 24.6,
          "mass_kg_per_km": 1043.8,
          "minimum_conductor_breaking_force_N": 80190
        },
        {
          "source_row_id": "10kV-light-210/10",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 210
            },
            {
              "material": "steel",
              "cross_section_mm2": 10
            }
          ],
          "conductor_diameter_mm": 19,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 24,
          "mass_kg_per_km": 831.1,
          "minimum_conductor_breaking_force_N": 45140
        },
        {
          "source_row_id": "10kV-light-210/25",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 210
            },
            {
              "material": "steel",
              "cross_section_mm2": 25
            }
          ],
          "conductor_diameter_mm": 20,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 25,
          "mass_kg_per_km": 987.9,
          "minimum_conductor_breaking_force_N": 65990
        },
        {
          "source_row_id": "10kV-light-210/35",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 210
            },
            {
              "material": "steel",
              "cross_section_mm2": 35
            }
          ],
          "conductor_diameter_mm": 20.4,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 25.4,
          "mass_kg_per_km": 1058,
          "minimum_conductor_breaking_force_N": 74250
        },
        {
          "source_row_id": "10kV-light-210/50",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 210
            },
            {
              "material": "steel",
              "cross_section_mm2": 50
            }
          ],
          "conductor_diameter_mm": 20.9,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 25.9,
          "mass_kg_per_km": 1166.8,
          "minimum_conductor_breaking_force_N": 90830
        },
        {
          "source_row_id": "10kV-light-240/30",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 240
            },
            {
              "material": "steel",
              "cross_section_mm2": 30
            }
          ],
          "conductor_diameter_mm": 21.6,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 26.6,
          "mass_kg_per_km": 1134.5,
          "minimum_conductor_breaking_force_N": 75620
        },
        {
          "source_row_id": "10kV-light-240/40",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 240
            },
            {
              "material": "steel",
              "cross_section_mm2": 40
            }
          ],
          "conductor_diameter_mm": 21.7,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 26.7,
          "mass_kg_per_km": 1177.1,
          "minimum_conductor_breaking_force_N": 83370
        },
        {
          "source_row_id": "10kV-light-240/55",
          "core_count": 1,
          "rated_voltage": "10kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 240
            },
            {
              "material": "steel",
              "cross_section_mm2": 55
            }
          ],
          "conductor_diameter_mm": 22.4,
          "nominal_insulation_thickness_mm": 2.5,
          "outer_diameter_mm": 27.4,
          "mass_kg_per_km": 1326.7,
          "minimum_conductor_breaking_force_N": 102100
        }
      ],
      "scope": "Calculated dimensions and mass of the original model/voltage table. Two material sections describe one reinforced conductor, not two cable cores. Generic selection ranges remain separate."
    }
  },
  "category_ids": [
    "overhead-cables"
  ],
  "english_name": "ACSR/XLPE 10kV Overhead Cable",
  "english_name_modules": [
    {
      "type": "materials",
      "value": "ACSR/XLPE"
    },
    {
      "type": "rated_voltage",
      "value": "10kV"
    },
    {
      "type": "product_type",
      "value": "Overhead Cable"
    }
  ],
  "display_identity": {
    "voltage_class": null,
    "qualifiers": [],
    "suffix_origin": "none",
    "notes": [
      "No website suffix is added; the display model preserves the source model."
    ],
    "model_label": "JKLGYJ/Q",
    "title": "JKLGYJ/Q — Overhead Cable",
    "enquiry_reference": {
      "source_model": "JKLGYJ/Q",
      "product_id": "xr-steel-core-al-overhead-jklgyj_q",
      "rated_voltage": "10kV",
      "instruction": "Quote the source model and product_id, together with the required rated voltage, core configuration and cross-section. Website suffixes are reference labels, not manufacturer ordering codes."
    }
  }
}