  "product_id": "xr-steel-core-al-overhead-jklgyj",
  "family_id": "steel-core-al-overhead",
  "model": "JKLGYJ",
  "source_notation": "JKLGYJ",
  "rated_voltage": "1kV",
  "specification_ranges": [
    {
      "profile_id": "1kv-declared-component-ranges",
      "range_type": "source_table_exact_or_conditioned_combination",
      "composition": {
        "aluminum_cross_section_mm2": {
          "min": 25,
          "max": 300
        },
        "steel_core_cross_section_mm2": {
          "min": 4,
          "max": 70
        }
      },
      "constraint_note": "The page states component ranges but does not declare arbitrary pairability for the 1 kV model."
    }
  ],
  "construction": {
    "conductor_material": "steel_reinforced_aluminum",
    "insulation_material": "xlpe",
    "outer_sheath_material": "none",
    "screen": {
      "present": false,
      "type": "none"
    },
    "armor": {
      "present": false,
      "type": "none"
    },
    "conductor_form": "stranded",
    "conductor_screen_cases": [
      {
        "rated_voltage": "1kV",
        "present": false,
        "type": "none"
      }
    ]
  },
  "functions": {},
  "cross_section_examples": [
    {
      "example_id": "steel-al-1kV",
      "basis": "manual_diagram",
      "scope": "model_diagram",
      "not_to_scale": true,
      "configuration_is_orderable_specification": false,
      "nodes": [
        {
          "node_id": "cable",
          "parent_id": null,
          "kind": "assembly",
          "count": 1,
          "layers": []
        },
        {
          "node_id": "aluminum-conductor",
          "parent_id": "cable",
          "kind": "core",
          "count": 1,
          "layers": [
            {
              "kind": "conductor",
              "material": "aluminum",
              "form": "stranded"
            },
            {
              "kind": "insulation",
              "material": "xlpe"
            }
          ]
        },
        {
          "node_id": "steel-centre",
          "parent_id": "aluminum-conductor",
          "kind": "reinforcement",
          "count": 1,
          "layers": [],
          "material": "steel"
        }
      ],
      "illustrated_counts": {
        "cores": 1,
        "groups": 0,
        "tubes": 0,
        "reinforcements": 1
      },
      "applicable_rated_voltage": "1kV",
      "note": "One steel-reinforced aluminium conductor. The central steel reinforcement is not a separate insulated electrical core. The drawn strand texture does not specify a manufacturing wire count."
    }
  ],
  "technical_details": {
    "applications": {
      "basis": "declared",
      "values": [
        "Overhead power transmission and distribution lines"
      ]
    },
    "dimensional_table": {
      "basis": "declared",
      "reported_row_count": 29,
      "rows": [
        {
          "source_row_id": "1kV-10/2",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 10
            },
            {
              "material": "steel",
              "cross_section_mm2": 2
            }
          ],
          "conductor_diameter_mm": 4.5,
          "nominal_insulation_thickness_mm": 1,
          "outer_diameter_mm": 6.5,
          "mass_kg_per_km": 71.2,
          "minimum_conductor_breaking_force_N": 2411,
          "range_note": "This detailed row is printed below the generic 25 mm2 selection minimum; retained as a source table row, not added to the selectable range."
        },
        {
          "source_row_id": "1kV-16/3",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 16
            },
            {
              "material": "steel",
              "cross_section_mm2": 3
            }
          ],
          "conductor_diameter_mm": 5.6,
          "nominal_insulation_thickness_mm": 1.2,
          "outer_diameter_mm": 8,
          "mass_kg_per_km": 107,
          "minimum_conductor_breaking_force_N": 6106,
          "range_note": "This detailed row is printed below the generic 25 mm2 selection minimum; retained as a source table row, not added to the selectable range."
        },
        {
          "source_row_id": "1kV-25/4",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 25
            },
            {
              "material": "steel",
              "cross_section_mm2": 4
            }
          ],
          "conductor_diameter_mm": 7,
          "nominal_insulation_thickness_mm": 1.2,
          "outer_diameter_mm": 9.4,
          "mass_kg_per_km": 153.1,
          "minimum_conductor_breaking_force_N": 9290
        },
        {
          "source_row_id": "1kV-35/6",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 35
            },
            {
              "material": "steel",
              "cross_section_mm2": 6
            }
          ],
          "conductor_diameter_mm": 8.2,
          "nominal_insulation_thickness_mm": 1.4,
          "outer_diameter_mm": 11,
          "mass_kg_per_km": 210,
          "minimum_conductor_breaking_force_N": 12630
        },
        {
          "source_row_id": "1kV-50/8",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 50
            },
            {
              "material": "steel",
              "cross_section_mm2": 8
            }
          ],
          "conductor_diameter_mm": 9.6,
          "nominal_insulation_thickness_mm": 1.4,
          "outer_diameter_mm": 12.4,
          "mass_kg_per_km": 274.6,
          "minimum_conductor_breaking_force_N": 16870
        },
        {
          "source_row_id": "1kV-50/30",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 50
            },
            {
              "material": "steel",
              "cross_section_mm2": 30
            }
          ],
          "conductor_diameter_mm": 11.6,
          "nominal_insulation_thickness_mm": 1.4,
          "outer_diameter_mm": 14.4,
          "mass_kg_per_km": 465.8,
          "minimum_conductor_breaking_force_N": 42620
        },
        {
          "source_row_id": "1kV-70/10",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 70
            },
            {
              "material": "steel",
              "cross_section_mm2": 10
            }
          ],
          "conductor_diameter_mm": 11.4,
          "nominal_insulation_thickness_mm": 1.4,
          "outer_diameter_mm": 14.2,
          "mass_kg_per_km": 367.8,
          "minimum_conductor_breaking_force_N": 23390
        },
        {
          "source_row_id": "1kV-70/40",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 70
            },
            {
              "material": "steel",
              "cross_section_mm2": 40
            }
          ],
          "conductor_diameter_mm": 13.6,
          "nominal_insulation_thickness_mm": 1.4,
          "outer_diameter_mm": 16.4,
          "mass_kg_per_km": 619.6,
          "minimum_conductor_breaking_force_N": 58330
        },
        {
          "source_row_id": "1kV-95/15",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 95
            },
            {
              "material": "steel",
              "cross_section_mm2": 15
            }
          ],
          "conductor_diameter_mm": 13.6,
          "nominal_insulation_thickness_mm": 1.6,
          "outer_diameter_mm": 16.8,
          "mass_kg_per_km": 506.5,
          "minimum_conductor_breaking_force_N": 35000
        },
        {
          "source_row_id": "1kV-95/20",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 95
            },
            {
              "material": "steel",
              "cross_section_mm2": 20
            }
          ],
          "conductor_diameter_mm": 13.9,
          "nominal_insulation_thickness_mm": 1.6,
          "outer_diameter_mm": 17.1,
          "mass_kg_per_km": 536.8,
          "minimum_conductor_breaking_force_N": 27200
        },
        {
          "source_row_id": "1kV-120/7",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 120
            },
            {
              "material": "steel",
              "cross_section_mm2": 7
            }
          ],
          "conductor_diameter_mm": 14.5,
          "nominal_insulation_thickness_mm": 1.6,
          "outer_diameter_mm": 17.7,
          "mass_kg_per_km": 512.2,
          "minimum_conductor_breaking_force_N": 27570
        },
        {
          "source_row_id": "1kV-120/20",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 120
            },
            {
              "material": "steel",
              "cross_section_mm2": 20
            }
          ],
          "conductor_diameter_mm": 15.1,
          "nominal_insulation_thickness_mm": 1.6,
          "outer_diameter_mm": 18.3,
          "mass_kg_per_km": 604.7,
          "minimum_conductor_breaking_force_N": 41000
        },
        {
          "source_row_id": "1kV-120/25",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 120
            },
            {
              "material": "steel",
              "cross_section_mm2": 25
            }
          ],
          "conductor_diameter_mm": 15.7,
          "nominal_insulation_thickness_mm": 1.6,
          "outer_diameter_mm": 18.9,
          "mass_kg_per_km": 670,
          "minimum_conductor_breaking_force_N": 47880
        },
        {
          "source_row_id": "1kV-120/70",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 120
            },
            {
              "material": "steel",
              "cross_section_mm2": 70
            }
          ],
          "conductor_diameter_mm": 18,
          "nominal_insulation_thickness_mm": 1.6,
          "outer_diameter_mm": 21.2,
          "mass_kg_per_km": 1057.4,
          "minimum_conductor_breaking_force_N": 98370
        },
        {
          "source_row_id": "1kV-150/8",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 150
            },
            {
              "material": "steel",
              "cross_section_mm2": 8
            }
          ],
          "conductor_diameter_mm": 16,
          "nominal_insulation_thickness_mm": 1.8,
          "outer_diameter_mm": 19.6,
          "mass_kg_per_km": 627.1,
          "minimum_conductor_breaking_force_N": 32860
        },
        {
          "source_row_id": "1kV-150/20",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 150
            },
            {
              "material": "steel",
              "cross_section_mm2": 20
            }
          ],
          "conductor_diameter_mm": 16.7,
          "nominal_insulation_thickness_mm": 1.8,
          "outer_diameter_mm": 20.3,
          "mass_kg_per_km": 721.3,
          "minimum_conductor_breaking_force_N": 46630
        },
        {
          "source_row_id": "1kV-150/25",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 150
            },
            {
              "material": "steel",
              "cross_section_mm2": 25
            }
          ],
          "conductor_diameter_mm": 17.1,
          "nominal_insulation_thickness_mm": 1.8,
          "outer_diameter_mm": 20.7,
          "mass_kg_per_km": 776.9,
          "minimum_conductor_breaking_force_N": 54110
        },
        {
          "source_row_id": "1kV-150/35",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 150
            },
            {
              "material": "steel",
              "cross_section_mm2": 35
            }
          ],
          "conductor_diameter_mm": 17.5,
          "nominal_insulation_thickness_mm": 1.8,
          "outer_diameter_mm": 21.1,
          "mass_kg_per_km": 855.7,
          "minimum_conductor_breaking_force_N": 65020
        },
        {
          "source_row_id": "1kV-185/10",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 185
            },
            {
              "material": "steel",
              "cross_section_mm2": 10
            }
          ],
          "conductor_diameter_mm": 18,
          "nominal_insulation_thickness_mm": 2,
          "outer_diameter_mm": 22,
          "mass_kg_per_km": 790.9,
          "minimum_conductor_breaking_force_N": 40880
        },
        {
          "source_row_id": "1kV-185/25",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 185
            },
            {
              "material": "steel",
              "cross_section_mm2": 25
            }
          ],
          "conductor_diameter_mm": 18.9,
          "nominal_insulation_thickness_mm": 2,
          "outer_diameter_mm": 22.9,
          "mass_kg_per_km": 922.2,
          "minimum_conductor_breaking_force_N": 59420
        },
        {
          "source_row_id": "1kV-185/30",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 185
            },
            {
              "material": "steel",
              "cross_section_mm2": 30
            }
          ],
          "conductor_diameter_mm": 18.9,
          "nominal_insulation_thickness_mm": 2,
          "outer_diameter_mm": 22.9,
          "mass_kg_per_km": 948.5,
          "minimum_conductor_breaking_force_N": 64320
        },
        {
          "source_row_id": "1kV-185/45",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 185
            },
            {
              "material": "steel",
              "cross_section_mm2": 45
            }
          ],
          "conductor_diameter_mm": 19.6,
          "nominal_insulation_thickness_mm": 2,
          "outer_diameter_mm": 23.6,
          "mass_kg_per_km": 1070.9,
          "minimum_conductor_breaking_force_N": 80190
        },
        {
          "source_row_id": "1kV-210/10",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 210
            },
            {
              "material": "steel",
              "cross_section_mm2": 10
            }
          ],
          "conductor_diameter_mm": 19,
          "nominal_insulation_thickness_mm": 2,
          "outer_diameter_mm": 23,
          "mass_kg_per_km": 867.4,
          "minimum_conductor_breaking_force_N": 45140
        },
        {
          "source_row_id": "1kV-210/25",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 210
            },
            {
              "material": "steel",
              "cross_section_mm2": 25
            }
          ],
          "conductor_diameter_mm": 20,
          "nominal_insulation_thickness_mm": 2,
          "outer_diameter_mm": 24,
          "mass_kg_per_km": 1015.9,
          "minimum_conductor_breaking_force_N": 65990
        },
        {
          "source_row_id": "1kV-210/35",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 210
            },
            {
              "material": "steel",
              "cross_section_mm2": 35
            }
          ],
          "conductor_diameter_mm": 20.4,
          "nominal_insulation_thickness_mm": 2,
          "outer_diameter_mm": 24.4,
          "mass_kg_per_km": 1086.8,
          "minimum_conductor_breaking_force_N": 74250
        },
        {
          "source_row_id": "1kV-210/50",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 210
            },
            {
              "material": "steel",
              "cross_section_mm2": 50
            }
          ],
          "conductor_diameter_mm": 20.9,
          "nominal_insulation_thickness_mm": 2,
          "outer_diameter_mm": 24.9,
          "mass_kg_per_km": 1196.5,
          "minimum_conductor_breaking_force_N": 90830
        },
        {
          "source_row_id": "1kV-240/30",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 240
            },
            {
              "material": "steel",
              "cross_section_mm2": 30
            }
          ],
          "conductor_diameter_mm": 21.6,
          "nominal_insulation_thickness_mm": 2.2,
          "outer_diameter_mm": 26,
          "mass_kg_per_km": 1192.3,
          "minimum_conductor_breaking_force_N": 75620
        },
        {
          "source_row_id": "1kV-240/40",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 240
            },
            {
              "material": "steel",
              "cross_section_mm2": 40
            }
          ],
          "conductor_diameter_mm": 21.7,
          "nominal_insulation_thickness_mm": 2.2,
          "outer_diameter_mm": 26.1,
          "mass_kg_per_km": 1235.1,
          "minimum_conductor_breaking_force_N": 83370
        },
        {
          "source_row_id": "1kV-240/55",
          "core_count": 1,
          "rated_voltage": "1kV",
          "conductor_components": [
            {
              "material": "aluminum",
              "cross_section_mm2": 240
            },
            {
              "material": "steel",
              "cross_section_mm2": 55
            }
          ],
          "conductor_diameter_mm": 22.4,
          "nominal_insulation_thickness_mm": 2.2,
          "outer_diameter_mm": 26.8,
          "mass_kg_per_km": 1386.9,
          "minimum_conductor_breaking_force_N": 102100
        }
      ],
      "scope": "Original steel/aluminium component tables. The named JKLGYJ model row states 1 kV. Unnamed standard 10 kV rows are preserved internally with pending model applicability, not offered as confirmed JKLGYJ specifications."
    }
  },
  "category_ids": [
    "overhead-cables"
  ],
  "english_name": "ACSR/XLPE 1kV Overhead Cable",
  "english_name_modules": [
    {
      "type": "materials",
      "value": "ACSR/XLPE"
    },
    {
      "type": "rated_voltage",
      "value": "1kV"
    },
    {
      "type": "product_type",
      "value": "Overhead Cable"
    }
  ],
  "display_identity": {
    "voltage_class": "LV",
    "qualifiers": [],
    "suffix_origin": "none",
    "notes": [
      "No website suffix is added; the display model preserves the source model."
    ],
    "model_label": "JKLGYJ",
    "title": "JKLGYJ — Overhead Cable",
    "enquiry_reference": {
      "source_model": "JKLGYJ",
      "product_id": "xr-steel-core-al-overhead-jklgyj",
      "rated_voltage": "1kV",
      "instruction": "Quote the source model and product_id, together with the required rated voltage, core configuration and cross-section. Website suffixes are reference labels, not manufacturer ordering codes."
    }
  }
}