  "product_id": "xr-mineral-copper-sheath-flexible-0.6-1-wd_yttw",
  "family_id": "mineral-copper-sheath-flexible-0.6-1",
  "model": "WD-YTTW",
  "source_notation": "WD-YTTW",
  "rated_voltage": "0.6/1kV",
  "specification_ranges": [
    {
      "profile_id": "1-core-10-630",
      "core_configurations": [
        "1 core"
      ],
      "cross_section_mm2": {
        "min": 10,
        "max": 630
      },
      "range_type": "declared_continuous_range_not_expanded"
    },
    {
      "profile_id": "2-4-and-3plus1-2.5-240",
      "core_configurations": [
        "2 cores",
        "3 cores",
        "4 cores",
        "3+1 core"
      ],
      "cross_section_mm2": {
        "min": 2.5,
        "max": 240
      },
      "range_type": "declared_continuous_range_not_expanded"
    },
    {
      "profile_id": "5-and-split-2.5-240",
      "core_configurations": [
        "5 cores",
        "3+2 cores",
        "4+1 core"
      ],
      "cross_section_mm2": {
        "min": 2.5,
        "max": 240
      },
      "range_type": "declared_continuous_range_not_expanded"
    }
  ],
  "construction": {
    "conductor_material": "copper",
    "insulation_material": "mica_tape",
    "outer_sheath_material": "polyolefin",
    "screen": {
      "present": false,
      "type": "none"
    },
    "armor": {
      "present": false,
      "type": "none"
    },
    "conductor_form": "stranded",
    "metal_sheath_material": "copper",
    "insulation_components": [
      "mica_tape"
    ],
    "metal_sheath_form": "corrugated"
  },
  "functions": {
    "flame_retardant": true,
    "flame_retardant_class": null,
    "fire_resistant": true,
    "low_smoke_halogen_free": true
  },
  "cross_section_examples": [
    {
      "example_id": "mineral-copper-five-core",
      "basis": "manual_diagram",
      "scope": "model_diagram",
      "not_to_scale": true,
      "configuration_is_orderable_specification": false,
      "nodes": [
        {
          "node_id": "cable",
          "parent_id": null,
          "kind": "assembly",
          "count": 1,
          "layers": [
            {
              "kind": "binder",
              "material": "inorganic_fire_retardant_tape"
            },
            {
              "kind": "metal_sheath",
              "material": "copper"
            },
            {
              "kind": "outer_sheath",
              "material": "polyolefin"
            }
          ]
        },
        {
          "node_id": "cores",
          "parent_id": "cable",
          "kind": "core",
          "count": 5,
          "layers": [
            {
              "kind": "conductor",
              "material": "copper",
              "form": "stranded"
            },
            {
              "kind": "insulation",
              "material": "mica_tape"
            }
          ]
        },
        {
          "node_id": "interstitial-filler",
          "parent_id": "cable",
          "kind": "filler",
          "count": 1,
          "layers": [],
          "material": "flame_retardant_rope"
        }
      ],
      "illustrated_counts": {
        "cores": 5,
        "groups": 0,
        "tubes": 0,
        "reinforcements": 0
      }
    }
  ],
  "technical_details": {
    "applications": {
      "basis": "declared",
      "values": [
        "Power distribution, lighting and fire-safety circuits",
        "High-rise and public buildings, hospitals and schools",
        "Industrial installations requiring fire-resistant circuits"
      ]
    },
    "manufacturing_description": {
      "basis": "declared",
      "values": [
        "Flexible construction permits continuous manufacture, delivery on drums and conventional cable-laying methods."
      ]
    },
    "construction_notes": {
      "basis": "declared",
      "values": [
        "Mica-based inorganic mineral insulation",
        "Inorganic composite fire-resistant wrapping",
        "Continuously welded corrugated copper sheath"
      ]
    },
    "minimum_bending_radius": {
      "basis": "declared",
      "cases": [
        {
          "conditions": "D < 7 mm",
          "min": 2,
          "unit": "D"
        },
        {
          "conditions": "7 <= D < 12 mm",
          "min": 3,
          "unit": "D"
        },
        {
          "conditions": "12 <= D < 15 mm",
          "min": 4,
          "unit": "D"
        },
        {
          "conditions": "D >= 15 mm",
          "min": 6,
          "unit": "D"
        }
      ],
      "diameter_definition": "D is the actual overall cable diameter.",
      "conditions": "Inside bend radius in the general mineral-cable installation section."
    },
    "installation_guidance": {
      "basis": "declared",
      "values": [
        "Do not twist, knot or drag the cable across abrasive surfaces.",
        "Fix at bends and on both sides of intermediate joints.",
        "Separate single-core circuits by at least twice the cable diameter; closer spacing requires current-rating derating.",
        "Use an outer protective sheath in corrosive environments and for buried or conduit installation."
      ]
    },
    "maximum_fixing_spacing": {
      "basis": "declared",
      "cases": [
        {
          "conditions": "D < 9 mm",
          "horizontal_max_mm": 600,
          "vertical_max_mm": 800
        },
        {
          "conditions": "9 <= D < 15 mm",
          "horizontal_max_mm": 900,
          "vertical_max_mm": 1200
        },
        {
          "conditions": "D >= 15 mm",
          "horizontal_max_mm": 1500,
          "vertical_max_mm": 2000
        }
      ],
      "diameter_definition": "D is the overall cable diameter."
    },
    "termination_guidance": {
      "basis": "declared",
      "values": [
        "Seal cut ends promptly against moisture if the cable will not be terminated immediately.",
        "Follow the manufacturer's termination and jointing procedure.",
        "Keep metallic sheath swarf out of the insulation and recheck insulation resistance during termination."
      ]
    },
    "insulation_resistance": {
      "basis": "declared",
      "cases": [
        {
          "conditions": "Cable length > 100 m",
          "min": 100,
          "unit": "MOhm.km"
        },
        {
          "conditions": "Cable length < 100 m",
          "min": 1000,
          "unit": "MOhm"
        }
      ],
      "conditions": "The source does not specify the boundary case at exactly 100 m."
    },
    "voltage_test": {
      "basis": "declared",
      "unit": "V",
      "value": 3500,
      "supply": "AC",
      "frequency": "Power frequency",
      "duration_s": 300,
      "conditions": "Between conductors and between a conductor and the copper sheath."
    },
    "single_core_fixing_guidance": {
      "basis": "declared",
      "values": [
        "Do not use ferromagnetic material such as iron wire to tie or fix single-core cables."
      ]
    },
    "maximum_conductor_temperature": {
      "basis": "declared",
      "max": 90,
      "unit": "degC",
      "conditions": "Continuous operation"
    },
    "conductor_copper_purity": {
      "basis": "declared",
      "value": 99.99,
      "unit": "%",
      "material": "oxygen_free_copper",
      "conditions": "Handbook material declaration; not a batch assay."
    },
    "fire_test_claims": {
      "basis": "declared",
      "cases": [
        {
          "test": "fire_only",
          "temperature_c": 800,
          "duration_min": 90
        },
        {
          "test": "BS6387_C",
          "temperature_c": 950,
          "duration_min": 180
        },
        {
          "test": "BS6387_W",
          "temperature_c": 650,
          "initial_fire_duration_min": 15,
          "fire_and_water_duration_min": 15
        },
        {
          "test": "BS6387_Z",
          "temperature_c": 950,
          "fire_and_mechanical_shock_duration_min": 15
        }
      ],
      "conditions": "General mineral-cable handbook claim of circuit integrity under the stated tests; not an independent certificate or an unconditional fire rating."
    },
    "continuous_manufactured_length_capability": {
      "basis": "declared",
      "max": 2000,
      "unit": "m",
      "conditions": "General manufacturing capability up to this length; availability for each individual specification is not established."
    },
    "expansion_and_vibration_bends": {
      "basis": "declared",
      "minimum_radius_D": 6,
      "shapes": [
        "S",
        "omega"
      ],
      "conditions": [
        "Large temperature variation",
        "Vibrating equipment connections",
        "Building settlement or expansion joints",
        "Long straight cable runs"
      ]
    },
    "natural_meander_allowance": {
      "basis": "declared",
      "maximum_excursion_D": 2,
      "exclusive_max": true,
      "conditions": "Natural meandering during laying; D is the overall cable diameter."
    },
    "support_span": {
      "basis": "declared",
      "cases": [
        {
          "diameter_max_mm": 20,
          "diameter_max_inclusive": true,
          "horizontal_max_mm": 400,
          "vertical_max_mm": 1500
        },
        {
          "diameter_min_mm": 20,
          "diameter_min_inclusive": false,
          "horizontal_max_mm": 800,
          "vertical_max_mm": 1000
        }
      ],
      "conditions": "Bracket or tray support span; distinct from the separate maximum fixing-point spacing table."
    },
    "ferromagnetic_conduit_restriction": {
      "basis": "declared",
      "individual_single_core_in_ferromagnetic_conduit_permitted": false,
      "conditions": "Route the circuit conductors together. If this is impossible, the source requires measures against eddy currents; installation design is still required."
    }
  },
  "category_ids": [
    "mineral-insulated",
    "power-cables",
    "fire-resistant",
    "flame-retardant",
    "lszh"
  ],
  "english_name": "CU/Mica Tape/Polyolefin 0.6/1kV LSZH Flame-retardant Fire-resistant Power Cable",
  "english_name_modules": [
    {
      "type": "materials",
      "value": "CU/Mica Tape/Polyolefin"
    },
    {
      "type": "rated_voltage",
      "value": "0.6/1kV"
    },
    {
      "type": "features",
      "value": "LSZH Flame-retardant Fire-resistant"
    },
    {
      "type": "product_type",
      "value": "Power Cable"
    }
  ],
  "display_identity": {
    "voltage_class": null,
    "qualifiers": [],
    "suffix_origin": "none",
    "notes": [
      "No website suffix is added; the display model preserves the source model."
    ],
    "model_label": "WD-YTTW",
    "title": "WD-YTTW — Power Cable",
    "enquiry_reference": {
      "source_model": "WD-YTTW",
      "product_id": "xr-mineral-copper-sheath-flexible-0.6-1-wd_yttw",
      "rated_voltage": "0.6/1kV",
      "instruction": "Quote the source model and product_id, together with the required rated voltage, core configuration and cross-section. Website suffixes are reference labels, not manufacturer ordering codes."
    }
  }
}