  "product_id": "xr-irradiated-rubber-flexible-cable-ycw",
  "family_id": "irradiated-rubber-flexible-cable",
  "model": "YCW",
  "source_notation": "YCW",
  "rated_voltage": "450/750V",
  "specification_ranges": [
    {
      "profile_id": "core-and-section-range",
      "cross_section_mm2": {
        "min": 2.5,
        "max": 150
      },
      "range_type": "declared_selectable_range",
      "constraint_note": "Core-count and cross-section ranges are independently declared. Individual combinations and voltage-group applicability are not established by this response.",
      "core_count": {
        "min": 1,
        "max": 5
      }
    }
  ],
  "construction": {
    "conductor_material": "copper",
    "insulation_material": "irradiated_rubber",
    "outer_sheath_material": "irradiated_rubber",
    "screen": {
      "present": false,
      "type": "none"
    },
    "armor": {
      "present": false,
      "type": "none"
    },
    "conductor_form": "flexible_stranded",
    "conductor_class": 5
  },
  "functions": {
    "weather_resistant": true,
    "oil_resistant": true
  },
  "cross_section_examples": [
    {
      "example_id": "rubber-1-core",
      "basis": "manual_diagram",
      "scope": "model_diagram",
      "not_to_scale": true,
      "configuration_is_orderable_specification": false,
      "nodes": [
        {
          "node_id": "cable",
          "parent_id": null,
          "kind": "assembly",
          "count": 1,
          "layers": [
            {
              "kind": "outer_sheath",
              "material": "irradiated_rubber"
            }
          ]
        },
        {
          "node_id": "cores",
          "parent_id": "cable",
          "kind": "core",
          "count": 1,
          "layers": [
            {
              "kind": "conductor",
              "material": "copper",
              "form": "flexible_stranded"
            },
            {
              "kind": "insulation",
              "material": "irradiated_rubber"
            }
          ]
        }
      ],
      "illustrated_counts": {
        "cores": 1,
        "groups": 0,
        "tubes": 0,
        "reinforcements": 0
      }
    },
    {
      "example_id": "rubber-3-core",
      "basis": "manual_diagram",
      "scope": "model_diagram",
      "not_to_scale": true,
      "configuration_is_orderable_specification": false,
      "nodes": [
        {
          "node_id": "cable",
          "parent_id": null,
          "kind": "assembly",
          "count": 1,
          "layers": [
            {
              "kind": "binder"
            },
            {
              "kind": "outer_sheath",
              "material": "irradiated_rubber"
            }
          ]
        },
        {
          "node_id": "cores",
          "parent_id": "cable",
          "kind": "core",
          "count": 3,
          "layers": [
            {
              "kind": "conductor",
              "material": "copper",
              "form": "flexible_stranded"
            },
            {
              "kind": "insulation",
              "material": "irradiated_rubber"
            }
          ]
        },
        {
          "node_id": "filler",
          "parent_id": "cable",
          "kind": "filler",
          "count": 1,
          "layers": []
        }
      ],
      "illustrated_counts": {
        "cores": 3,
        "groups": 0,
        "tubes": 0,
        "reinforcements": 0
      }
    }
  ],
  "technical_details": {
    "applications": {
      "basis": "declared",
      "values": [
        "Movable supply leads for electrical appliances, machinery and tools",
        "Indoor and outdoor electrical equipment"
      ]
    },
    "construction_notes": {
      "basis": "declared",
      "values": [
        "Class 5 flexible conductor.",
        "Insulation and sheath crosslinked by electron-beam irradiation."
      ]
    },
    "minimum_bending_requirement": {
      "basis": "declared",
      "unit": "D",
      "value": 6,
      "conditions": "Source wording: minimum bending requirement; the radius/diameter convention is not explicit.",
      "diameter_definition": "D is the overall cable diameter."
    },
    "declared_properties": {
      "basis": "declared",
      "values": [
        "Weather resistance and some oil resistance; intended for outdoor or oil-contact applications."
      ]
    },
    "maximum_conductor_temperature": {
      "basis": "declared",
      "max": 70,
      "unit": "degC",
      "conditions": "Continuous operation"
    },
    "conductor_class": {
      "basis": "declared",
      "value": 5,
      "standard": "GB/T 3956",
      "conditions": "Flexible copper conductor."
    }
  },
  "category_ids": [
    "rubber-cables",
    "equipment-wires"
  ],
  "english_name": "CU/Irradiated Rubber/Irradiated Rubber 450/750V Equipment Wire",
  "english_name_modules": [
    {
      "type": "materials",
      "value": "CU/Irradiated Rubber/Irradiated Rubber"
    },
    {
      "type": "rated_voltage",
      "value": "450/750V"
    },
    {
      "type": "product_type",
      "value": "Equipment Wire"
    }
  ],
  "display_identity": {
    "voltage_class": null,
    "qualifiers": [],
    "suffix_origin": "none",
    "notes": [
      "No website suffix is added; the display model preserves the source model."
    ],
    "model_label": "YCW",
    "title": "YCW — Equipment Wire",
    "enquiry_reference": {
      "source_model": "YCW",
      "product_id": "xr-irradiated-rubber-flexible-cable-ycw",
      "rated_voltage": "450/750V",
      "instruction": "Quote the source model and product_id, together with the required rated voltage, core configuration and cross-section. Website suffixes are reference labels, not manufacturer ordering codes."
    }
  }
}