  "product_id": "xr-industrial-devicenet-de05s_24a2c_22a2c_f_eab",
  "family_id": "industrial-devicenet",
  "model": "DE05S-24A2C-22A2C-F-EAB",
  "source_notation": "DE05S-24A2C-22A2C-F-EAB",
  "rated_voltage": "300V",
  "specification_ranges": [
    {
      "profile_id": "source-row",
      "range_type": "source_table_exact_or_conditioned_combination",
      "composition": [
        {
          "core_count": 2,
          "awg": 24
        },
        {
          "core_count": 2,
          "awg": 22
        }
      ]
    }
  ],
  "construction": {
    "conductor_material": "tinned_copper",
    "insulation_material": "foamed_pe_and_pvc_by_core_function",
    "outer_sheath_material": "pvc",
    "screen": {
      "present": true,
      "type": "tinned_copper_wire_braid"
    },
    "armor": {
      "present": false,
      "type": "none"
    },
    "conductor_form": "extra_fine_stranded",
    "separation": {
      "present": true,
      "type": "flexible_peelable_aluminum_foil_tape"
    },
    "insulation_by_core_function": [
      {
        "core_function": "signal",
        "material": "foamed_pe"
      },
      {
        "core_function": "power",
        "material": "pvc"
      }
    ]
  },
  "functions": {
    "flame_retardant": true,
    "flame_retardant_class": null,
    "low_smoke_halogen_free": false,
    "oil_resistant": true,
    "abrasion_resistant": true,
    "weather_resistant": true,
    "cold_resistant": true,
    "declared_drag_chain_cycles": 5000000
  },
  "cross_section_examples": [
    {
      "example_id": "manual-illustration",
      "basis": "manual_diagram",
      "scope": "model_diagram",
      "not_to_scale": true,
      "configuration_is_orderable_specification": false,
      "nodes": [
        {
          "node_id": "cable",
          "parent_id": null,
          "kind": "assembly",
          "count": 1,
          "layers": [
            {
              "kind": "separator",
              "material": "flexible_peelable_aluminum_foil_tape"
            },
            {
              "kind": "metal_screen",
              "material": "tinned_copper_wire_braid"
            },
            {
              "kind": "outer_sheath",
              "material": "pvc"
            }
          ]
        },
        {
          "node_id": "signal-pair",
          "parent_id": "cable",
          "kind": "group",
          "count": 1,
          "layers": [
            {
              "kind": "group_boundary",
              "physical_layer": false
            }
          ]
        },
        {
          "node_id": "signal-cores",
          "parent_id": "signal-pair",
          "kind": "core",
          "count": 2,
          "layers": [
            {
              "kind": "conductor",
              "material": "tinned_copper",
              "form": "extra_fine_stranded"
            },
            {
              "kind": "insulation",
              "material": "foamed_pe"
            }
          ]
        },
        {
          "node_id": "power-pair",
          "parent_id": "cable",
          "kind": "group",
          "count": 1,
          "layers": [
            {
              "kind": "group_boundary",
              "physical_layer": false
            }
          ]
        },
        {
          "node_id": "power-cores",
          "parent_id": "power-pair",
          "kind": "core",
          "count": 2,
          "layers": [
            {
              "kind": "conductor",
              "material": "tinned_copper",
              "form": "extra_fine_stranded"
            },
            {
              "kind": "insulation",
              "material": "pvc"
            }
          ]
        },
        {
          "node_id": "unlabelled-center",
          "parent_id": "cable",
          "kind": "unlabelled_component",
          "count": 1,
          "layers": []
        }
      ],
      "illustrated_counts": {
        "cores": 4,
        "groups": 2,
        "tubes": 0,
        "reinforcements": 0
      }
    }
  ],
  "technical_details": {
    "applications": {
      "basis": "declared",
      "values": [
        "DeviceNet industrial networks with a data pair and a power pair"
      ]
    },
    "minimum_bending_radius_fixed": {
      "basis": "declared",
      "unit": "D",
      "min": 7,
      "conditions": "Fixed installation",
      "diameter_definition": "D is the actual overall cable diameter."
    },
    "minimum_bending_radius_moving": {
      "basis": "declared",
      "unit": "D",
      "min": 14,
      "conditions": "Moving installation",
      "diameter_definition": "D is the actual overall cable diameter."
    },
    "flame_test_requirement": {
      "basis": "declared",
      "values": [
        "IEC 60332-1",
        "CEI 20-35"
      ],
      "conditions": "Catalogue-declared flame-test requirement."
    },
    "temperature_fixed": {
      "basis": "declared",
      "unit": "degC",
      "min": -15,
      "max": 80,
      "conditions": "Fixed installation"
    },
    "temperature_moving": {
      "basis": "declared",
      "unit": "degC",
      "min": -5,
      "max": 70,
      "conditions": "Moving installation"
    },
    "voltage_test": {
      "basis": "declared",
      "unit": "V",
      "value": 1500,
      "supply": "AC",
      "duration_s": 60
    },
    "characteristic_impedance": {
      "basis": "declared",
      "unit": "Ohm",
      "nominal": 120,
      "tolerance": 15,
      "conditions": "Measurement frequency is not stated."
    },
    "insulation_resistance": {
      "basis": "declared",
      "cases": [
        {
          "conditions": "Signal cores",
          "min": 1000,
          "unit": "MOhm.km"
        },
        {
          "conditions": "Power cores",
          "min": 10,
          "unit": "MOhm.km"
        }
      ],
      "conditions": "Source signal value is 1 GOhm.km; converted to 1000 MOhm.km."
    },
    "installation_guidance": {
      "basis": "declared",
      "values": [
        "Unreel without introducing spiral twist.",
        "Do not tie or clamp cables together in the moving bend zone.",
        "Avoid bending immediately at terminals and prevent oil entering cable ends.",
        "Use the model-specific bending limits in preference to generic installation illustrations."
      ]
    },
    "drag_chain_guidance": {
      "basis": "declared",
      "values": [
        "Allow the cable to follow the drag-chain centreline without tension or excessive slack.",
        "Secure at the ends, not in the moving section.",
        "Separate different diameters with dividers and keep cables apart from air hoses."
      ],
      "conditions": "For drag-chain use, where applicable to the selected product."
    },
    "separator": {
      "basis": "declared",
      "values": [
        "Peelable aluminium-foil wrapping."
      ]
    },
    "conductor_class": {
      "basis": "declared",
      "value": 6,
      "standard": "IEC 60228 / VDE 0295"
    },
    "screen_coverage": {
      "basis": "declared",
      "wire_coverage_percent": 85,
      "optical_coverage": {
        "min": 85
      },
      "conditions": "Catalogue screen-coverage statement; no screening-performance value is inferred."
    },
    "dimensional_table": {
      "basis": "declared",
      "values_are_approximate": false,
      "reported_row_count": 1,
      "rows": [
        {
          "specification_profile_id": "source-row",
          "composition": [
            {
              "core_count": 2,
              "awg": 24
            },
            {
              "core_count": 2,
              "awg": 22
            }
          ],
          "outer_diameter_mm": 6.9,
          "mass_kg_per_km": 68
        }
      ]
    },
    "drag_chain_installation_limits": {
      "basis": "declared",
      "generic_minimum_bend_radius_outer_diameter_multiple": 6,
      "moving_section_clamping_permitted": false,
      "end_fixing_required": true,
      "cable_separation_required": true,
      "dividers_required_for_large_diameter_differences": true,
      "dividers_required_between_cables_and_air_hoses": true,
      "conditions": "Applicable only where the selected model permits drag-chain service. The generic 6D illustration does not reduce any larger model-specific moving or fixed minimum bending radius."
    }
  },
  "category_ids": [
    "industrial-bus",
    "industrial-flexible",
    "cold-resistant",
    "flame-retardant",
    "screened"
  ],
  "english_name": "Tinned CU/Foamed PE/PVC/PVC 300V Flame-retardant Screened Industrial Bus Cable",
  "english_name_modules": [
    {
      "type": "materials",
      "value": "Tinned CU/Foamed PE/PVC/PVC"
    },
    {
      "type": "rated_voltage",
      "value": "300V"
    },
    {
      "type": "features",
      "value": "Flame-retardant Screened"
    },
    {
      "type": "product_type",
      "value": "Industrial Bus Cable"
    }
  ],
  "display_identity": {
    "voltage_class": null,
    "qualifiers": [],
    "suffix_origin": "none",
    "notes": [
      "No website suffix is added; the display model preserves the source model."
    ],
    "model_label": "DE05S-24A2C-22A2C-F-EAB",
    "title": "DE05S-24A2C-22A2C-F-EAB — Industrial Bus Cable",
    "enquiry_reference": {
      "source_model": "DE05S-24A2C-22A2C-F-EAB",
      "product_id": "xr-industrial-devicenet-de05s_24a2c_22a2c_f_eab",
      "rated_voltage": "300V",
      "instruction": "Quote the source model and product_id, together with the required rated voltage, core configuration and cross-section. Website suffixes are reference labels, not manufacturer ordering codes."
    }
  }
}