  "product_id": "xr-bare-conductors-tjr2",
  "family_id": "bare-conductors",
  "model": "TJR2",
  "source_notation": "TJR2",
  "specification_ranges": [
    {
      "profile_id": "nominal-total-section-range",
      "cross_section_mm2": {
        "min": 2.5,
        "max": 50
      },
      "range_type": "declared_selectable_range",
      "constraint_note": "Nominal total conductor cross-section. Aluminium, steel and other component areas and individual constructions are not specified by this response."
    }
  ],
  "construction": {
    "conductor_material": "copper",
    "insulation_material": "none",
    "outer_sheath_material": "none",
    "screen": {
      "present": false,
      "type": "none"
    },
    "armor": {
      "present": false,
      "type": "none"
    },
    "conductor_form": "soft_stranded",
    "conductor_temper": "soft"
  },
  "functions": {},
  "cross_section_examples": [
    {
      "example_id": "bare-single-conductor",
      "basis": "manual_model_table",
      "scope": "declared_component_structure",
      "not_to_scale": true,
      "configuration_is_orderable_specification": false,
      "nodes": [
        {
          "node_id": "assembly",
          "parent_id": null,
          "kind": "assembly",
          "count": 1,
          "layers": []
        },
        {
          "node_id": "conductor",
          "parent_id": "assembly",
          "kind": "core",
          "count": 1,
          "layers": [
            {
              "kind": "conductor",
              "material": "copper",
              "form": "soft_stranded"
            }
          ]
        }
      ],
      "illustrated_counts": {
        "cores": 1,
        "groups": 0,
        "tubes": 0,
        "reinforcements": 0
      },
      "note": "One bare electrical conductor, not multiple insulated cable cores. Steel or alloy core strands are contained inside the outer conductor strands. No insulation or jacket is added."
    }
  ],
  "technical_details": {
    "applications": {
      "basis": "declared",
      "values": [
        "Overhead electrical power lines"
      ]
    },
    "delivery_conditions": {
      "basis": "declared",
      "length_tolerance_percent": 0.5,
      "maximum_short_length_share_percent": 5,
      "minimum_short_length_fraction": "1/3",
      "conditions": "The printed length tolerance is plus or minus 5 per mille (0.5%). Short lengths are at least one third of the manufacturing length; other lengths may be agreed."
    }
  },
  "category_ids": [
    "bare-conductors",
    "overhead-conductors"
  ],
  "english_name": "CU Bare Conductor",
  "english_name_modules": [
    {
      "type": "materials",
      "value": "CU"
    },
    {
      "type": "product_type",
      "value": "Bare Conductor"
    }
  ],
  "display_identity": {
    "voltage_class": null,
    "qualifiers": [],
    "suffix_origin": "none",
    "notes": [
      "No website suffix is added; the display model preserves the source model."
    ],
    "model_label": "TJR2",
    "title": "TJR2 — Bare Conductor",
    "enquiry_reference": {
      "source_model": "TJR2",
      "product_id": "xr-bare-conductors-tjr2",
      "rated_voltage": null,
      "instruction": "Quote the source model and product_id, together with the required rated voltage, core configuration and cross-section. Website suffixes are reference labels, not manufacturer ordering codes."
    }
  }
}