  "product_id": "xr-b2-wire-450-750-wdzb2n_byj",
  "family_id": "b2-wire-450-750",
  "model": "WDZB2N-BYJ",
  "source_notation": "WDZB2N-BY J",
  "rated_voltage": "Up to 450/750V",
  "specification_ranges": [
    {
      "profile_id": "single-core-wire",
      "core_configurations": [
        "1 core"
      ],
      "cross_section_mm2": {
        "min": 1.5,
        "max": 400
      },
      "range_type": "declared_selectable_range"
    }
  ],
  "construction": {
    "conductor_material": "copper",
    "insulation_material": "irradiated_crosslinked_polyethylene",
    "outer_sheath_material": "none",
    "screen": {
      "present": false,
      "type": "none"
    },
    "armor": {
      "present": false,
      "type": "none"
    },
    "fire_barrier": "present",
    "conductor_form": "rigid"
  },
  "functions": {
    "flame_retardant": true,
    "flame_retardant_class": [
      "B2"
    ],
    "fire_resistant": true,
    "low_smoke_halogen_free": true
  },
  "cross_section_examples": [
    {
      "example_id": "wire-source-configuration",
      "basis": "manual_model_table_and_diagram",
      "scope": "model_table_structure_applied_to_illustrated_configuration",
      "not_to_scale": true,
      "model_structure_complete": false,
      "configuration_is_orderable_specification": false,
      "nodes": [
        {
          "node_id": "cable",
          "parent_id": null,
          "kind": "assembly",
          "count": 1,
          "layers": []
        },
        {
          "node_id": "cores",
          "parent_id": "cable",
          "kind": "core",
          "count": 1,
          "layers": [
            {
              "kind": "conductor",
              "material": "copper"
            },
            {
              "kind": "insulation",
              "material": "irradiated_crosslinked_polyethylene"
            }
          ]
        }
      ],
      "illustrated_counts": {
        "cores": 1,
        "groups": 0,
        "tubes": 0,
        "reinforcements": 0
      },
      "note": "The B2 page illustrates the ordinary wire construction; the N model fire-resistance declaration is retained, but its additional layer placement is not labelled in this drawing."
    }
  ],
  "technical_details": {
    "dimensional_table": {
      "basis": "declared",
      "reported_row_count": 17,
      "rows": [
        {
          "source_row_id": "b2-byj:1.5",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 1.5
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 3.9,
          "mass_kg_per_km": 30.2,
          "reference_ampacity": {
            "unit": "A",
            "reference": 14,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:2.5",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 2.5
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 4.3,
          "mass_kg_per_km": 41,
          "reference_ampacity": {
            "unit": "A",
            "reference": 20,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:4",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 4
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 4.7,
          "mass_kg_per_km": 56.6,
          "reference_ampacity": {
            "unit": "A",
            "reference": 27,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:6",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 6
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 5.2,
          "mass_kg_per_km": 77.5,
          "reference_ampacity": {
            "unit": "A",
            "reference": 34,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:10",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 10
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 6.9,
          "mass_kg_per_km": 129.2,
          "reference_ampacity": {
            "unit": "A",
            "reference": 49,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:16",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 16
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 7.9,
          "mass_kg_per_km": 189.8,
          "reference_ampacity": {
            "unit": "A",
            "reference": 67,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:25",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 25
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 9.6,
          "mass_kg_per_km": 288.5,
          "reference_ampacity": {
            "unit": "A",
            "reference": 91,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:35",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 35
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 10.4,
          "mass_kg_per_km": 380.3,
          "reference_ampacity": {
            "unit": "A",
            "reference": 110,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:50",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 50
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 11.9,
          "mass_kg_per_km": 512.3,
          "reference_ampacity": {
            "unit": "A",
            "reference": 140,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:70",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 70
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 13.7,
          "mass_kg_per_km": 707.3,
          "reference_ampacity": {
            "unit": "A",
            "reference": 180,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:95",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 95
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 15.8,
          "mass_kg_per_km": 974.7,
          "reference_ampacity": {
            "unit": "A",
            "reference": 225,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:120",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 120
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 17.5,
          "mass_kg_per_km": 1206.1,
          "reference_ampacity": {
            "unit": "A",
            "reference": 265,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:150",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 150
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 19.1,
          "mass_kg_per_km": 1491.2,
          "reference_ampacity": {
            "unit": "A",
            "reference": 305,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:185",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 185
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 21.1,
          "mass_kg_per_km": 1860.8,
          "reference_ampacity": {
            "unit": "A",
            "reference": 360,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:240",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 240
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 24,
          "mass_kg_per_km": 2414.7,
          "reference_ampacity": {
            "unit": "A",
            "reference": 435,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:300",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 300
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 26.4,
          "mass_kg_per_km": 2977.5,
          "reference_ampacity": {
            "unit": "A",
            "reference": 505,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        },
        {
          "source_row_id": "b2-byj:400",
          "composition": [
            {
              "core_count": 1,
              "cross_section_mm2": 400
            }
          ],
          "core_count": 1,
          "outer_diameter_mm": 29.7,
          "mass_kg_per_km": 3856.2,
          "reference_ampacity": {
            "unit": "A",
            "reference": 595,
            "conditions": "Reference table value only. Installation conditions are not specified in this table; not a universal current rating."
          }
        }
      ],
      "scope": "Original model-specific reference table. Dimensions are approximate and mass is a reference value. These rows do not expand the separately declared selectable ranges."
    },
    "applications": {
      "basis": "declared",
      "values": [
        "Building and equipment wiring"
      ]
    },
    "minimum_laying_temperature": {
      "basis": "declared",
      "unit": "degC",
      "min": 0
    },
    "minimum_bending_radius": {
      "basis": "declared",
      "unit": "D",
      "min": 6,
      "conditions": "Installation",
      "diameter_definition": "D is the actual overall cable diameter."
    },
    "reaction_to_fire_requirements": {
      "basis": "declared",
      "classification": "B2",
      "test_standard": "GB 31247-2014",
      "limits": [
        {
          "parameter": "Flame spread",
          "max": 2.5,
          "unit": "m"
        },
        {
          "parameter": "Peak heat release rate",
          "max": 60,
          "unit": "kW"
        },
        {
          "parameter": "Total heat release",
          "max": 30,
          "unit": "MJ",
          "duration_s": 1200
        },
        {
          "parameter": "Fire growth rate index",
          "max": 300,
          "unit": "W/s"
        },
        {
          "parameter": "Peak smoke production rate",
          "max": 1.5,
          "unit": "m2/s"
        },
        {
          "parameter": "Total smoke production",
          "max": 400,
          "unit": "m2",
          "duration_s": 1200
        },
        {
          "parameter": "Vertical flame spread",
          "max": 425,
          "unit": "mm"
        }
      ],
      "conditions": "Catalogue-declared class requirements; this record is not an individual product test report."
    },
    "handling_guidance": {
      "basis": "declared",
      "values": [
        "Keep drums upright and secure during lifting, transport and storage.",
        "Inspect for damage and check insulation resistance before installation.",
        "Provide allowance for vibration, thermal expansion and building movement."
      ]
    },
    "installation_guidance": {
      "basis": "declared",
      "values": [
        "Avoid twisting, knotting and dragging across sharp or abrasive surfaces.",
        "Fix the cable at bends and on both sides of joints.",
        "Do not use ferromagnetic ties or clamps around single-core cables.",
        "Provide mechanical protection where damage may occur."
      ]
    },
    "maximum_conductor_temperature": {
      "basis": "declared",
      "max": 90,
      "unit": "degC",
      "conditions": "Continuous operation. Temperature grades of 105, 125 and 150 degC require an explicit temperature designation in the model."
    },
    "installation_spacing": {
      "basis": "declared",
      "fixed_point_spacing_mm": [
        {
          "diameter_mm": {
            "less_than": 9
          },
          "horizontal_max": 600,
          "vertical_max": 800
        },
        {
          "diameter_mm": {
            "minimum": 9,
            "less_than": 15
          },
          "horizontal_max": 900,
          "vertical_max": 1200
        },
        {
          "diameter_mm": {
            "minimum": 15
          },
          "horizontal_max": 1500,
          "vertical_max": 2000
        }
      ],
      "support_span_mm": [
        {
          "diameter_mm": {
            "maximum": 20
          },
          "horizontal_max": 400,
          "vertical_max": 1500
        },
        {
          "diameter_mm": {
            "greater_than": 20
          },
          "horizontal_max": 800,
          "vertical_max": 1000
        }
      ],
      "natural_snaking_amplitude": {
        "less_than_outer_diameter_multiple": 2
      },
      "single_core_circuit_separation": {
        "minimum_outer_diameter_multiple": 2,
        "closer_spacing_requires_ampacity_derating": true
      },
      "single_core_fixings_must_be_nonmagnetic": true,
      "conditions": "Handbook installation guidance. D is the cable outer diameter. Fixed-point distances and support spans are distinct tables, not interchangeable limits."
    },
    "movement_allowance_bends": {
      "basis": "declared",
      "shapes": [
        "S",
        "omega"
      ],
      "minimum_radius_outer_diameter_multiple": 15,
      "conditions": [
        "Large ambient temperature changes",
        "Wiring to vibrating equipment",
        "Building settlement or expansion joints",
        "An otherwise entirely straight cable run"
      ]
    }
  },
  "category_ids": [
    "equipment-wires",
    "fire-resistant",
    "flame-retardant",
    "b2",
    "lszh"
  ],
  "english_name": "CU/Irradiated XLPE Up to 450/750V LSZH Flame-retardant B2 Fire-resistant Equipment Wire",
  "english_name_modules": [
    {
      "type": "materials",
      "value": "CU/Irradiated XLPE"
    },
    {
      "type": "rated_voltage",
      "value": "Up to 450/750V"
    },
    {
      "type": "features",
      "value": "LSZH Flame-retardant B2 Fire-resistant"
    },
    {
      "type": "product_type",
      "value": "Equipment Wire"
    }
  ],
  "display_identity": {
    "voltage_class": null,
    "qualifiers": [],
    "suffix_origin": "none",
    "notes": [
      "No website suffix is added; the display model preserves the source model."
    ],
    "model_label": "WDZB2N-BYJ",
    "title": "WDZB2N-BYJ — Equipment Wire",
    "enquiry_reference": {
      "source_model": "WDZB2N-BYJ",
      "product_id": "xr-b2-wire-450-750-wdzb2n_byj",
      "rated_voltage": "Up to 450/750V",
      "instruction": "Quote the source model and product_id, together with the required rated voltage, core configuration and cross-section. Website suffixes are reference labels, not manufacturer ordering codes."
    }
  }
}